Usulan Perancangan Pemasangan Alarm Detector dan Sprinkler pada Kampus C Universitas Dirgantara Marsekal Suryadarama

Authors

  • Achmad Takbiriyantono Universitas Dirgantara Marsekal Suryadarma Author
  • Waspada Tedja Bhirawa Universitas Dirgantara Marsekal Suryadarma Author
  • Basuki Arianto Universitas Dirgantara Marsekal Suryadarma Author
  • Wardaya Universitas Dirgantara Marsekal Suryadarma Author

DOI:

https://doi.org/10.35968/21wpfx05

Keywords:

Kesehatan dan Keselamatan Lingkungan, Alarm Detektor, Sprinkler Fishbone Diagram

Abstract

Universitas Dirgantara Marsekal Suryadarma saat ini memanfaatkan Campus A, Campus B, dan Campus C yang baru dibangun. Penelitian ini berfokus pada Campus C, sebuah gedung bertiga lantai yang memerlukan langkah-langkah keselamatan kebakaran yang andal. Bahaya kebakaran di gedung ini meliputi instalasi listrik dan bahan bangunan yang mudah terbakar. Untuk mengatasi risiko ini, penelitian ini menggunakan diagram sebab-akibat (diagram Fishbone) untuk menganalisis faktor-faktor penyebab bahaya kebakaran, yang dikategorikan ke dalam Aspek Pekerja, Bahan Baku, Mesin, Metode, dan Lingkungan. Dengan menggunakan metode 5W+1H Quality, penelitian ini merekomendasikan pemasangan 132 alat pemadam kebakaran otomatis (sprinkler) dengan pipa ¾" dan saluran pipa sepanjang 460 meter. Kebutuhan pasokan air adalah 277 m³/menit, yang memerlukan sistem pompa dengan kapasitas 277 m³/menit. Tiga pompa dengan kapasitas masing-masing 100 m³/jam dan satu pompa cadangan direkomendasikan untuk kapasitas ini. Selain itu, diusulkan tangki penyimpanan air dengan kapasitas 300 m³ untuk 60 menit, dengan ukuran panjang 4 meter, lebar 5 meter, dan kedalaman 1,5 meter. Penelitian ini juga merekomendasikan penerapan Prosedur Operasi Standar (SOP) K3 (Kesehatan dan Keselamatan Kerja) untuk meningkatkan keselamatan dan manajemen bahaya kebakaran di Campus C. SOP ini mencakup perbaikan pada faktor manusia, bahan, mesin, metode, dan lingkungan di Campus C.

 

The building facilities currently used by Universitas Dirgantara Marsekal Suryadarma (Unsurya) is Campus A and Campus B and the new Campus C. In this research examined campus C Unsurya, which is a three (3) floor building. The building must be equipped with reliable fire safety facilities. There are several functions of space that can trigger fires, namely electrical installations and flammable building materials. Based on the background above, adequate active protection means are needed in accordance with applicable regulations. Cause-and-effect diagrams / Fishbone diagrams are used to analyze the factors that cause fire hazards. The factors that influence and cause fire hazards can generally be classified as follows: Workers, Raw Materials, Machines, Methods, and Environment. 5W+1H Quality using to determine recommendation. Based on calculations, it was determined to place 132 sprinklers to overcome the danger of fire with a quantity of ¾" pipe material with a pipe line 460 meters long. Meanwhile, the water supply is 277 m3/minute. With the required water supply, a pump with a pump capacity capable of producing 277 m3/minute is needed. With this capacity, three pumps with a capacity of 100 m3 /hour and one spare pump can be used. A water storage tank is needed for 300 m3 for 60 minutes with a length of 4 meters, width of 5 meters and depth of 1.5 meters. It is proposed to use a Standard Operating Procedure (SOP) regarding K3 or safety and how to handle fire hazards in the Unsurya Campus C building which includes improvements to human factors, materials, machines, methods and the environment of the Campus C Unsurya.

 

Downloads

Published

2024-08-10

How to Cite

Usulan Perancangan Pemasangan Alarm Detector dan Sprinkler pada Kampus C Universitas Dirgantara Marsekal Suryadarama. (2024). Jurnal Manajemen Kesehatan Dan Keperawatan, 1(2), 62-71. https://doi.org/10.35968/21wpfx05

Similar Articles

1-10 of 13

You may also start an advanced similarity search for this article.